NT2003B Development of fluidic and mechanical nanosystems, First author, Dec 2025

Topological and parametric optimization of DC-iEK devices against Joule heating

AUTHORS

Ari Emilio Núñez Menéndez

SimulationHealth

Summary

NT2003B Development of fluidic and mechanical nanosystems, First author

[SUMMARY PENDING]

What I did

What I did

FEM simulation in COMSOL of a microfluidic device with SU-8 posts; 25 µm fillets and a parametric sweep of gaps.

Key results

Key results

−27 % mean temperature, −40 % power, T max < 30 °C

Key result

Figures

Figures

COMSOL, optimized
COMSOL temperature map of the optimized DC-iEK device